General Information
Price Genesis® 'Q' series Fan Powered Terminals are designed to take advantage of silencer acoustical properties producing an extremely quiet unit while maintaining all the Price Genesis® standard features. (Refer to Price Genesis® catalog for all standard features and benefits associated to the fan powered unit.)

The entry section of the discharge silencer is custom designed, directly coupled, mating perfectly with the Genesis® terminal. The Q silencer is designed to be aerodynamically compatible with the fan discharge velocity profile. Thereby it dramatically reduces the discharge noise, without compromising the overall pressure drop and capacity of the Genesis® unit. The unique internal geometry of the discharge silencer further reduces fan noise by limiting line of sight. Noise reduction is so effective that typically no downstream insulation is required to achieve room noise levels below NC 35.

The inlet attenuator section of the Q Series Genesis® terminal has been enhanced to further reduce already low radiated noise levels of this unit.

The complete fan terminal/ silencer assembly has been tested and certified in accordance with AHRI Standard 880. The discharge and radiated sound data presented in the catalog is based on complete assemblies tested in the Price lab. No calculations or system effect assumptions are required to determine silencer performance.

Price Genesis® 'Q' Terminals units are supplied with the latest motor technology: ECM -- Electronically Commutated Motor. The ECM motor is a brushless DC motor design with a built in inverter and a microprocessor based motor controller. The ECM motor has several features which make it superior to conventional electric motors:
• Factory set fan flow
• Energy efficient
• Long life
• Low operating temperature
• Programmable
• Wide operating range
Each ECM motor supplied with the Genesis Terminal is factory preset with the Price ENERSAVE™ operating program. The ENERSAVE™ program has been developed to provide consistent, repeatable fan volume and optimal energy efficiency.

For more specific information on ECM motor technology and benefits see page F436-F439.
Each Price fan powered terminal unit receives a full operational check before shipment and arrives factory calibrated in accordance to project specifications. This means costly setup delays are avoided.
Units are ETL certified to meet UL 1995 and CSA C22.2 No. 236.

Price Genesis® Terminals are specifically designed to attenuate radiated noise which is a major concern with fan powered terminals, particularly at high capacities. An acoustical return air inlet section and thick acoustic insulation reduces radiated noise levels in the room by as much as 10 NC below conventional fan powered terminals.


Features
  • Supplied with discharge silencer section and enhanced inlet attenuator.
  • Recirculating fan section operates ­continuously.
  • Primary air section controls are pressure independent.
  • 20 gauge construction zinc-coated steel housing, mechanically sealed, leak-resistant construction.
  • 1 in. [25] thick, min. 1.5 lb density fiberglass internal insulation which meets requirements of UL 181 and NFPA-90A. Several other Price liner options available (FF- fiber free foam, FB- foil faced rigid fiberglass board, SM solid metal liner(dual wall), PM perforated metal liner, AFPM- foil faced fiberglass with perforated liner). See page F381 for detailed information about Price liners selection
  • Four insulated and gasketed blower access panels. Each equipped with quick-access hand operated snap latches for easy, fast, and tool-free field servicing.
  • ECM – electronically commutated motor 60 Hz, single phase, 115, 240, 277 VAC.
  • Motor is mounted on vibration isolators.
  • Blower/motor assembly is removable as one unit.
  • Solid state speed controller, SCR for adjusting fan section air flow.
  • Certified in accordance with the AHRI 880 certification program.
  • Units are ETL listed to meet UL1995 and CSA No. 236
  • A 2 in. collar is provided for inlet duct connection.
    Product Selection Checklist

  1. Select Unit Inlet Size based on control and acoustic parameters.
  2. Select Control type (Pneumatic, Digital) based on system design.
  3. Select Accessories (Inlet or Outlet, Attenuator) as required.
  4. Select Reheat Coil, if required.
  5. Select Control Sequence based on system design.
   
Features & Benefits
Quiet, reversible, accessible, energy efficient, ARI and ETL certified, loaded with options.
1. Reversible casing. Flips up side down for LH or RH configurations.   9. Gasketed access panels for quiet operation and air tight construction.
2. Heavy duty 20ga casing.   10. Thick fiberglass insulation w/variety of Price liner options. see Liners.
3. Unique 16 ga rigid blower isolation support.   11. Tool-free snap latches.
4. 4 access panels, each large enough to service motor blower assembly. Optional top and bottom access doors only with screws are also available (ATBS).   11. Tool-free snap latches.
  12. Quick connect for motor leads.
  13. Energy efficient ECM motor.
  14. Centered discharge.
5. Integral enhanced inlet actuator.   15. Discharge silencer.
6. Price superior SP300 Sensor technology.      
7. Single NEMA1 enclosure with fan and damper controls. One cover to access both.      
8. Primary air equalization screen.      
The pdfs are best viewed with Adobe Reader. Download it now.